RF Technology T70/T150 Page 5
1 OPERATING INSTRUCTIONS. 1.1.5 Alarm LED
1.1.5 ALARM LED
The Alarm LED can indicate several fault conditions if they are detected by the self
test program. The alarm indicator shows the highest priority fault present.
Transmitters using software issue 5 and higher use the cadence of the LED flash
sequence to indicate the alarm condition. Refer to table 1. Transmitter using
software issue 4 and lower use the LED flash rate to indicate the alarm condition.
Refer to table 2.
LED Flash Cadence Fault Condition
5 flashes, pause Synthesizer unlocked
4 flashes, pause Tuning voltage out of range
3 flashes, pause Low forward power
2 flashes, pause High reverse (reflected) power
1 flash, pause Low dc supply voltage
LED ON continuously Transmitter timed out
Table 1: Interpretations of LED flash cadence
Indication Fault Condition
Flashing, 8 per second Synthesizer unlocked
Flashing, 4 per second Tuning voltage outside correct range
Flashing, 2 per second Low forward power
Flashing, 1 per second High reverse power
Continuous dc supply voltage low or high
Table 2: Interpretations of LED flash speed, for early models
1.1.6 ALC LED
The ALC LED indicates that the transmitter output power is being controlled by an
external amplifier through the external ALC input.
1.1.7 REF LED
The REF LED indicates that the synthesizer frequency reference is locked to an
external reference.
1.1.8 TEST MIC.
The TEST MIC. DIN socket is provided for use with a standard mobile or handset
200 Ohm dynamic microphone. The external audio inputs are disabled when the TEST
MIC.'s PTT is on.
Comentarios a estos manuales